I. SPECIFICATIONS Dimensions: 13
½" W x 13 ½" H x 32 ¼" L II. STANDARD EQUIPMENTUnits are provided with: 10" diameter exhaust, 9" diameter direct drive centrifugal blower with a 115 volt motor; control panel, 3 speed switch, stainless steel cabinet with 2 lifting handles, side access panel to HEPA filter, 3-ply prefilter, and gasket seal high capacity HEPA filter. POWER
REQUIREMENT 3 SPEED SWITCH III. MAINTENANCE 1.
Pre-Filter: 2. HEPA Filter
12" x 12" x 4" or 12" x 12" x 12": Caution: HEPA filters are to be handled only by their frame. Do not touch the white media or separators as damage could result. 3. Catalytic Reaction Chamber: To replace the HEPA filter and catalytic reaction chamber, remove side access panel, slide out the dirty filter and chamber, reinsert new filter and chamber into unit and screw on side access panel. 4. Anti-microbial Elements: To replace anti-microbial elements, remove side access door. After removing HEPA filter and catalytic reaction chamber, remove upstream and downstream elements from clips. Replace with IAF anti-microbial elements following same procedure. Be careful when removing anti-microbial elements from holders; wear clean gloves during this operation. Replace with new IAF anti-microbial elements using clean gloves. DO NOT TOUCH ELEMENTS WITH BARE HANDS. Once new elements have been replaced, re-install all filters and side access door per enclosed instructions. To operate efficiently, elements must be clean at all times. Anti-microbial elements can be cleaned with rubbing alcohol applied with a clean cloth. IV. WARNING: 1. IN ORDER FOR OUR EQUIPMENT TO BE EFFECTIVE, FILTERS, CHAMBER AND ELEMENTS MUST BE CHANGED REGULARLY. BEFORE HANDLING OR REPLACING CONTAMINATED FILTERS OR ELEMENTS, CONTACT YOUR LOCAL HEALTH AUTHORITIES TO DETERMINE PROPER HANDLING AND DISPOSAL PROCEDURES. 2. DO NOT CHANGE FILTERS, CHAMBER OR ELEMENTS WHILE UNIT IS TURNED ON, AND NEVER LOOK DIRECTLY AT THE ANTI-MICROBIAL ELEMENTS WHEN THE UNIT IS OPERATING. 3. USE OF OUR EQUIPMENT OFFERS NO GUARANTEE THAT INDIVIDUALS WILL NOT BE INFECTED. USE OF OUR EQUIPMENT IS ONLY ONE STEP AMONG OTHERS TO PROTECT INDIVIDUALS FROM HARMFUL PATHOGENS. FURTHERMORE, OUR EQUIPMENT CAN ONLY KILL PATHOGENS THAT PASS THROUGH OUR EQUIPMENT. ALTHOUGH WE DO NOT CLAIM ANY SPECIFIC CAPABILITIES OF OUR FILTRATION SYSTEMS AT THIS TIME, WE FEEL OUR EQUIPMENT CAN PROVIDE YOU WITH SOME PROTECTION FROM THESE AGENTS. V. WARRANTY Motor, blower, and switch for 2 years. We Have a Model to fit your needs: |
Copyright © 2005 Shilog Medical Supply | Site Map | Contact Us |