MODEL DASH 5GB BIO-SECURITY SYSTEM SPECIFICATIONS

I. SPECIFICATIONS

Dimensions:                  13 ½" W x 13 ½" H x 32 ¼" L
Air Flow:                      Up to 400 CFM (3 speeds) Catalytic Reaction        
Chamber:                     Disposable 12" x 12" x 12"  
Pre-Filter:                     13" x 13", #15/40, 3-ply panel or 13" x 13" x 1" –  40% efficient pleat filter
HEPA Filter:                 12" x 12" x 12"
Anti-Microbial: 3 anti-microbial elements
Motor:                          3-speed, 1/2 HP with automatic overload
Current:                        115/60, 7 amps
Housing:                       Stainless steel
Weight:                         75 Lbs. (approximately)
Panel:                           3-speed switch, 7 amp, 115 volt current                       

II. STANDARD EQUIPMENT

Units are provided with:  10" diameter exhaust, 9" diameter direct drive centrifugal blower with a 115 volt motor; control panel, 3 speed switch, stainless steel cabinet with 2 lifting handles, side access panel to HEPA filter, 3-ply prefilter, and gasket seal high capacity HEPA filter.

POWER REQUIREMENT
Unit may be plugged into 115 volt, 7 amp service with ground.

3 SPEED SWITCH
Located in upper right-hand corner of control panel located on the side of the unit.

III. MAINTENANCE
Filters

1.  Pre-Filter:
13" x 13" ring panel, #15/40, 3-ply to be installed with white side out; the pink side is downstream.  The filter should be replaced when the colored material becomes discolored.  The life of this filter should be up to 2 months, depending on usage. The purpose of the pre-filter is to extend the life of the HEPA filters. Be sure to have a replacement supply of these filters in stock.

2.  HEPA Filter 12" x 12" x 4" or 12" x 12" x 12":
The purpose of the filter is to collect 99.97% of particles 0.3 micron size and larger.  The life of this filter is up to 2 years.  To replace the HEPA, remove side access panel, remove (2) wing nuts, the clamp strap and rod.  Finally, remove the dirty filter and replace with new filter.

Caution: HEPA filters are to be handled only by their frame.  Do not touch the white media or separators as damage could result.

3. Catalytic Reaction Chamber: 
The purpose of the chamber is to assist in the killing of bacteria and removal of VOCs.  Disposable catalytic reaction chamber - 12" x 12" x 12":  The life of this chamber is up to 12 months.

To replace the HEPA filter and catalytic reaction chamber, remove side access panel, slide out the dirty filter and chamber, reinsert new filter and chamber into unit and screw on side access panel.  

4.  Anti-microbial Elements:
3 – IAF anti-microbial elements need to be replaced every twelve (12) months.

To replace anti-microbial elements, remove side access door.  After removing HEPA filter and catalytic reaction chamber, remove upstream and downstream elements from clips.  Replace with IAF anti-microbial elements following same procedure.

Be careful when removing anti-microbial elements from holders; wear clean gloves during this operation.  Replace with new IAF anti-microbial elements using clean gloves.  DO NOT TOUCH ELEMENTS WITH BARE HANDS.  Once new elements have been replaced, re-install all filters and side access door per enclosed instructions.

To operate efficiently, elements must be clean at all times.  Anti-microbial elements can be cleaned with rubbing alcohol applied with a clean cloth.

IV.       WARNING:

 1. IN ORDER FOR OUR EQUIPMENT TO BE EFFECTIVE, FILTERS, CHAMBER AND ELEMENTS MUST BE CHANGED REGULARLY.  BEFORE HANDLING OR REPLACING CONTAMINATED FILTERS OR ELEMENTS, CONTACT YOUR LOCAL HEALTH AUTHORITIES TO DETERMINE PROPER HANDLING AND DISPOSAL PROCEDURES.

2. DO NOT CHANGE FILTERS, CHAMBER OR ELEMENTS WHILE UNIT IS TURNED ON, AND NEVER LOOK DIRECTLY AT THE ANTI-MICROBIAL ELEMENTS WHEN THE UNIT IS OPERATING. 

3. USE OF OUR EQUIPMENT OFFERS NO GUARANTEE THAT INDIVIDUALS WILL NOT BE INFECTED.  USE OF OUR EQUIPMENT IS ONLY ONE STEP AMONG OTHERS TO PROTECT INDIVIDUALS FROM HARMFUL PATHOGENS. FURTHERMORE, OUR EQUIPMENT CAN ONLY KILL PATHOGENS THAT PASS THROUGH OUR EQUIPMENT.  ALTHOUGH WE DO NOT CLAIM ANY SPECIFIC CAPABILITIES OF OUR FILTRATION SYSTEMS AT THIS TIME, WE FEEL OUR EQUIPMENT CAN PROVIDE YOU WITH SOME PROTECTION FROM THESE AGENTS.

V.         WARRANTY                                             

Motor, blower, and switch for 2 years.

We Have a Model to fit your needs:


GO HERE TO ORDER BIO-SECURITY SYSTEMS

 