>
Shilog Medical Supply
P.O. Box 1887
3551 Mt. Moriah Road
McAlester
Ok, 74502
Toll Free:
1-800-574-4868
McAlester:
1-918-423-4447
Fax:
918-423-5569
E-Mail Us

We Have a Model to fit your needs:


MODEL DASH 20GB BIO-SECURITY SYSTEM SPECIFICATIONS

I. SPECIFICATIONS

Dimensions:                  26" W x 31" H x 42" L
Air Flow:                      Up to 840, 930, and 1050 CFM (3 speeds)
Catalytic Reaction        
Chamber:                     Disposable 24" x 24" x 6"
Pre-Filters:                   24" x 24", #15/40, 3-ply ring panel
HEPA Filter:                 24" x 24" x 4"
Anti-Microbial:             12 anti-microbial elements
Motor:                          3-speed, ¾" HP with automatic overload
Current:                        115/60, 15 amps
Housing:                       16-Gauge Galvanized Steel
Weight:                         250 Lbs. (approximately)
Panel:                           3-speed switch, filter gauge, 15 amp circuit breaker

II. STANDARD EQUIPMENT

Units are provided with:  12" exhaust, 12" diameter direct drive centrifugal blower with a 115 volt motor; control panel with 15 amp circuit breaker, 3 speed switch, minihelic filter gauge, galvanized steel cabinet, 4 lifting handles, 4 swivel casters, HEPA retaining screen, 3-ply prefilter, 40% efficient pleat filter and HEPA filter, anti-microbial elements and catalytic reaction element.

POWER REQUIREMENT

Unit may be plugged into 115 volts or 100 volts, 15 amp service with ground.

CIRCUIT BREAKER

A 15 amp circuit breaker is located in the control panel.  When breaker trips, the round button marked “15” will protrude; to reset, turn speed control switch to off position, push in breaker and restart unit.  If breaker trips again, disconnect power cord and check for loose or damaged wiring.  Repairs must be done by a qualified electrical technician.

3 SPEED SWITCH

Located in upper right-hand corner of control panel.

FILTER GAUGE

A minihelic gauge is located in the center of the control panel. Gauge readings will help to determine when to change filters.  See Filter Section for further information.

III. LUBRICATION

Lubricate wheel bearings once a year using automotive grease.

IV. MAINTENANCE

Filters

1. Pre-Filters:

24" x 24" ring panel, #15/40, 3-ply to be installed with white side out; the colored side is downstream.  The filter should be replaced when the colored material becomes discolored.  The purpose of the pre-filter is to extend the life of the catalytic reaction chamber and HEPA filter, while keeping the anti-microbial elements clean. Be sure to have a replacement supply of these filter, chamber and elements in stock.

2. HEPA Filter 24" x 24" x 4": 

The purpose of the filter is to collect gas phase filtration media dust and dust particles 0.3 micron size and larger.  The life of the HEPA filter is up to 2 years.

 Caution: HEPA filters are to be handled only by their frame.  Do not touch the     white media or separators as damage could result.

 3.   Catalytic Reaction Chamber: 

The purpose of the chamber is to assist in the killing of bacteria and removal of VOCs.
Catalytic reaction chamber is 24" x 24" x 6".  The life of this chamber is up to 12 months.

To replace the HEPA filter and the catalytic reaction chamber, unscrew 4 –3 /8" nuts securing the HEPA and chamber.  Each rod has a retainer block to hold the HEPA and chamber in place. Finally, remove the filter and chamber.

 4.   Anti-microbial Elements:

 12 – IAF Anti-microbial elements need to be replaced every twelve (12) months.

 

To replace anti-microbial elements, remove side access door.  Remove elements from holders in the filter frame by pushing up and turning each element to remove the elements.  Replace with IAF anti-microbial elements following same procedure.

 

 Be careful when removing anti-microbial elements from holder; wear clean gloves                                        during this operation.  Replace with new IAF anti-microbial elements using clean                              gloves.  DO NOT TOUCH ELEMENTS WITH BARE HANDS.  Once new                                 elements have been replaced, re-install all filters and side access door per enclosed                                  instructions.

 

To operate efficiently, elements must be clean at all times.  Anti-microbial elements can be cleaned with rubbing alcohol applied with a clean cloth.

 V. WARNING:

1. IN ORDER FOR OUR EQUIPMENT TO BE EFFECTIVE, FILTERS, CHAMBERS AND ELEMENTS MUST BE CHANGED REGULARLY.  BEFORE HANDLING OR REPLACING CONTAMINATED FILTERS OR ELEMENTS, CONTACT YOUR LOCAL HEALTH AUTHORITIES TO DETERMINE PROPER HANDLING AND DISPOSAL PROCEDURES.

2. DO NOT CHANGE FILTERS, CHAMBER OR ELEMENTS WHILE UNIT IS TURNED ON, AND NEVER LOOK DIRECTLY AT THE ANTI-MICROBIAL ELEMENTS WHEN THE UNIT IS TURNED ON. 

3. USE OF OUR EQUIPMENT OFFERS NO GUARANTEE THAT INDIVIDUALS WILL NOT BE INFECTED.  OUR EQUIPMENT IS ONLY ONE STEP AMONG OTHERS TO PROTECT INDIVIDUALS FROM HARMFUL PATHOGENS. FURTHERMORE, WE KILL ONLY PATHOGENS THAT PASS THROUGH EQUIPMENT.  ALTHOUGH WE CANNOT CLAIM ANY SPECIFIC CAPABILITIES OF OUR FILTRATION SYSTEMS AT THIS TIME, WE FEEL WE CAN PROVIDE YOU WITH SOME PROTECTION FROM THESE AGENTS.

VI. WARRANTY:

      Motor, blower, and switch for 2 years.

We Have a Model to fit your needs:

Copyright © 2005 Shilog Medical Supply |  Site Map  |  Contact Us